MASS EXPORT CALCULATION AND ASSUMPTIONS
Fan Speed 240 cfm X 60 min/hr = 14,400 cubic feet/hour (cfh)
Assumption: 1 cu meter = 0.0283 cu ft
Calculation: 14,400 cfh x (0.0283 cu ft/m) = 407.52 cu meters/hr
Assumption: Air Mass Density= 1.2041 kg /cu meter (20 deg C at 101.325 kPa)
Calculation: 407.52 cu meter/hr x (1.2041 kg/cu meter)= 490.69kg/hr or 490690000 mg/hr
Hydrogen Peroxide (H2O2)
Historical Output Range: 25 -33 ppm
Mass of H202 at 25ppm continuous output
Lowest Assumption: 25 ppm~ 0.0025% of air volume
(vapor density of H202 is unknown per MSDS, but assume = air)
Calculation:
49069000 mg/hr X .000025 = 12,267.25 mg/hr H2O2
Mass of H202 at 33ppm continuous output
Highest Assumption: 33 ppm~ 0.0033% of air volume
(vapor density of H202 is unknown per MSDS, but assume = air)
Calculation:
49069000 mg/hr X .000033 = 16,192.77 mg/hr H2O2
Ozone (O3)
Historical Output: 38 to 53 ppm
Mass of 03 at 38PPM
Lowest Assumption: 38 ppm~ 0.0035% of air volume
(vapor density of 03 is 1.7 that of air)
Calculation:
490690000 mg/hr X .000038 = 18,646.22 mg/hr X 1.7 = 31,698.57 mg/hr O3
Mass of 03 at 53PPM
Highest Assumption: 50 ppm~ 0.0050% of air volume
(vapor density of 03 is 1.7 that of air)
Calculation:
490690000 mg/hr X .000050 = 24,534.5 mg/hr X 1.7 = 41,708.65 mg/hr O3